Noritz Error Code 52: Exhaust Blockage

Severity
Warning
Type
digital display
Where to look
front panel
Estimated repair cost: $100 — $350 (parts + labor)
Warning: Your Noritz water heater has detected an exhaust blockage, which could lead to carbon monoxide buildup. Turn off the unit immediately and call a professional.

How to Fix Noritz Code 52

  1. Step 1: Turn off the power to the water heater at the circuit breaker
  2. Step 2: Contact a licensed HVAC technician to diagnose and fix the issue
  3. Step 3: Do not attempt to operate the unit until a professional has resolved the issue

How to Reset Noritz Code 52

  1. Turn off the unit using the power button on the front panel.
  2. Turn off the gas supply valve.
  3. Turn off the circuit breaker supplying power to the unit. Wait 30 seconds.
  4. Restore power at the breaker, then open the gas valve.
  5. Turn the unit back on. If the error returns, the underlying issue needs repair.

Resetting clears the code from the display but does not fix the underlying fault. If the code returns after reset, proceed to the diagnostic steps above.

What Does Noritz Error Code 52 Mean?

Error code 52 on your Noritz water heater indicates that the exhaust system is blocked, preventing proper venting. This could be due to a buildup of lint, dust, or other debris. The unit has automatically shut down to ensure safety. Do not attempt to operate the unit until the issue is resolved by a professional.

Common Causes

  • Blockage in the exhaust vent due to lint, dust, or other debris
  • Faulty draft inducer fan
  • Incorrect venting configuration
  • Blockage in the combustion chamber

Diagnostic Steps

If... Check Expected
Exhaust vent is accessible Inspect the vent for blockages or obstructions Clear vent with no obstructions
Draft inducer fan is accessible Measure the fan's RPM using a tachometer Fan should spin at the manufacturer's specified RPM

Applicable Noritz Models

Replacement Parts

Part OEM Number Est. Cost Where to Buy
Exhaust Vent Kit NOR-EXVKIT
Draft Inducer Fan NOR-DIFAN

Related Codes on Same Models

Other codes that affect the same Noritz model families as 52.

Code Description Severity
12 Flame Loss Warning
14 Thermal Fuse Failure Warning
16 Over-Temperature Warning
29 Condensate Drain Issue Warning
31 Inlet Thermistor Failure Warning
32 Outlet Thermistor Failure Warning
33 Heat Exchanger Thermistor Failure Warning
43 Water Level/Neutralizer Issue Warning
59 Overheating Abnormality Warning
66 Bypass Flow Control Valve Failure Warning