Carrier Error Code 23: Pressure Switch Fault

Severity
Warning
Type
led blink pattern
Where to look
sight glass
Estimated repair cost: $75 — $200 (parts + labor)
Warning: Your Carrier furnace has detected a pressure switch fault, which prevents it from starting for safety reasons. A professional HVAC technician is needed to diagnose and repair the issue.

LED Blink Pattern

How to Fix Carrier Code 23

  1. Step 1: Check the air filter. A severely clogged filter can sometimes restrict airflow enough to trigger a pressure switch fault.
  2. Step 2: Visually inspect the vent pipes (both intake and exhaust) outside your home for any obvious obstructions like snow, ice, or debris. Safely clear any blockages you can reach.
  3. Step 3: If the problem persists after checking the filter and vents, contact a qualified HVAC technician to diagnose and repair the issue.

How to Reset Carrier Code 23

  1. Turn off the furnace power switch, usually located on or near the unit.
  2. Turn off the circuit breaker for the furnace. Wait 30 seconds.
  3. Restore power at the breaker and flip the furnace switch back on.
  4. Set the thermostat to call for heat. If the error code returns after 2-3 ignition attempts, the fault requires repair.

Resetting clears the code from the display but does not fix the underlying fault. If the code returns after reset, proceed to the diagnostic steps above.

What Does Carrier Error Code 23 Mean?

The Carrier 23 error code, indicated by a specific blinking pattern on the unit's LED, signifies a problem with the pressure switch circuit. This switch is a crucial safety component that verifies proper venting before allowing the furnace to ignite. When the furnace induces draft, the pressure switch should close, proving that exhaust gases will vent properly. If the control board does not see the switch close, it will display error code 23 and shut down the unit to prevent potential hazards.

Common Causes

  • Blocked vent pipe (intake or exhaust)
  • Failed pressure switch
  • Loose or disconnected pressure switch tubing
  • Faulty inducer motor
  • Defective control board

Diagnostic Steps

If... Check Expected
Furnace displays error code 23 Visually inspect pressure switch tubing for kinks, cracks, or disconnections Tubing is intact and properly connected to the pressure switch and inducer housing.
Tubing is OK With the furnace OFF, use a multimeter to measure the resistance across the pressure switch terminals Should read open circuit (infinite resistance).
Switch is open Start a call for heat, then measure voltage to the inducer motor 120VAC
Inducer voltage OK With the inducer running, use a manometer to measure pressure at the pressure switch port on the inducer housing. Should meet or exceed the pressure switch's rated actuation pressure (e.g., -0.5" WC)

Applicable Carrier Models

Replacement Parts

Part OEM Number Est. Cost Where to Buy
Pressure Switch
Inducer Motor 326461-756
Control Board HK42FZ004

Related Codes on Same Models

Other codes that affect the same Carrier model families as 23.

Code Description Severity
12 Blower On After Power Up Warning
13 Limit/Rollout Fault Critical
14 Ignition Lockout Critical
21 Gas Heating Lockout Critical
22 Abnormal Flame Critical
24 Secondary Voltage Fuse Warning
31 High Stage Pressure Fault Warning
32 Low Flame Sense Warning
33 Limit/Rollout Switch Lockout Critical
34 Ignition/Flame Sense Fault Warning