Trane Error Code 6: Polarity/Grounding Error

Severity
Warning
Type
led blink count
Where to look
sight glass
Estimated repair cost: $300 — $650 (parts + labor)
Warning: Your Trane HVAC system has encountered a Polarity/Grounding error, which requires professional attention.

LED Blink Pattern

How to Fix Trane Code 6

  1. Step 1: Turn off your HVAC system at the thermostat and the main electrical panel to ensure safety.
  2. Step 2: Inspect the electrical connections at the outdoor unit, if accessible, for any signs of damage or corrosion. Tighten any loose connections.
  3. Step 3: Contact a licensed HVAC technician to diagnose and repair the issue, as it requires professional expertise.

How to Reset Trane Code 6

  1. Turn off the furnace power switch, usually located on or near the unit.
  2. Turn off the circuit breaker for the furnace. Wait 30 seconds.
  3. Restore power at the breaker and flip the furnace switch back on.
  4. Set the thermostat to call for heat. If the error code returns after 2-3 ignition attempts, the fault requires repair.

Resetting clears the code from the display but does not fix the underlying fault. If the code returns after reset, proceed to the diagnostic steps above.

What Does Trane Error Code 6 Mean?

A Trane Polarity/Grounding error (code 6) indicates an issue with the electrical connections or grounding in your HVAC system. This error is triggered when the system detects an abnormal electrical condition, which could be due to a poor connection, a short circuit, or an improperly grounded component. It's crucial to address this issue promptly to prevent potential damage to your system and ensure its safe operation.

Common Causes

  • Improperly grounded or damaged electrical components
  • Loose or corroded electrical connections
  • Short circuit in the electrical system

Diagnostic Steps

If... Check Expected
Outdoor unit is running but not heating/cooling Measure the voltage at the control board using a multimeter Correct voltage (usually 24V AC)
Control board shows signs of damage or discoloration Inspect the control board for any visible damage or signs of overheating No visible damage or discoloration

Applicable Trane Models

Replacement Parts

Part OEM Number Est. Cost Where to Buy
Control Board Trane 130-8600-0000
Wiring Harness

Related Codes on Same Models

Other codes that affect the same Trane model families as 6.

Code Description Severity
2 System Lockout Warning
3 Pressure Switch Error Warning
4 Open Limit Switch Warning
5 Flame Sensed With Gas Off Warning
7 Gas Valve Circuit Error Warning
8 Low Flame Signal Warning
9 Igniter Problem Warning
FAST-FLASH Active Call for Heat Warning
SLOW-FLASH Normal Operation (Standby) Warning
STEADY-OFF No Power Warning