Rheem Error Code A095: DIP Switch Error
Warning: Your Rheem HVAC system has a DIP switch error, which may cause system malfunction or lockout. It's safe to troubleshoot, but call a professional if needed.
How to Fix Rheem Code A095
- Check your Rheem HVAC system's owner's manual for the correct DIP switch settings for your model.
- Locate the DIP switches on your system's control board. They are usually near the main control unit.
- Carefully inspect the switches for any signs of damage or dirt. If necessary, clean them gently with a soft, dry cloth.
- If the switches appear clean and undamaged, try resetting them according to the settings in your owner's manual. If the problem persists, call a professional HVAC technician.
How to Reset Rheem Code A095
- Turn off the unit using the power button on the front panel.
- Turn off the gas supply valve.
- Turn off the circuit breaker supplying power to the unit. Wait 30 seconds.
- Restore power at the breaker, then open the gas valve.
- Turn the unit back on. If the error returns, the underlying issue needs repair.
Resetting clears the code from the display but does not fix the underlying fault. If the code returns after reset, proceed to the diagnostic steps above.
What Does Rheem Error Code A095 Mean?
The Rheem A095 error code indicates a problem with the DIP switches on your HVAC control board. DIP switches are small, removable components that allow you to set specific parameters for your system. When the system detects an issue with these switches, it displays the A095 code and may lock out certain functions.
Common Causes
- Incorrect DIP switch settings
- Damaged or dirty DIP switches
- Loose or disconnected switch connections
Diagnostic Steps
| If... | Check | Expected |
|---|---|---|
| DIP switches are not set according to the owner's manual | Reset the DIP switches to the correct settings | System should function normally after resetting |
| DIP switches are dirty or damaged | Clean or replace the damaged switches | System should function normally after cleaning or replacement |
Applicable Rheem Models
- NCB(gas)
- NPE(electric)
- R801T(gas)
- R92E(electric)
- R92V(gas)
- RGE(gas)
- RH2T(electric)
- RNC(dual_fuel)
- RNE(electric)
- RNG(gas)
- RP16(electric)
- RPB(gas)
- RTGH(gas)
- Rheem Classic(gas)
- Rheem Classic 80 Plus(gas)
- Rheem Classic 80% Gas Furnace(gas)
- Rheem Classic 90 Plus(gas)
- Rheem Classic Plus Series(gas)
- Rheem Classic Series(dual_fuel)
- Rheem Prestige(gas)
- Rheem Prestige 95% Gas Furnace(gas)
- Rheem Prestige Series(gas)
Replacement Parts
| Part | OEM Number | Est. Cost | Where to Buy |
|---|---|---|---|
| DIP Switch Assembly | RHEEM 373209 | — | Find Part |
Related Codes on Same Models
Other codes that affect the same Rheem model families as A095.
| Code | Description | Severity |
|---|---|---|
| A001 | Ignition Failure | Warning |
| A021 | Over-Temperature | Warning |
| A031 | Inlet Thermistor Open/Short | Warning |
| A041 | Outlet Thermistor Open/Short | Warning |
| A043 | Water Level Error | Warning |
| A051 | Fan Motor Abnormality | Warning |
| A052 | Fan Motor Speed Error | Warning |
| A053 | Fan Motor Open Circuit | Warning |
| A054 | Fan Motor Overcurrent | Warning |
| A055 | Fan Motor Locked | Warning |