Lennox Error Code 4: High Limit Switch Open

Severity
Warning
Type
led blink count
Where to look
sight glass
Estimated repair cost: $75 — $200 (parts + labor)
Warning: Your Lennox HVAC system has detected a high temperature and has shut down to prevent damage. Call a professional for repair.

LED Blink Pattern

How to Fix Lennox Code 4

  1. Check if your air filter is clean. A clogged filter can restrict airflow and cause the system to overheat.
  2. Ensure that all vents are open and unobstructed to allow for proper airflow.
  3. If the issue persists, do not attempt to open the unit or perform any further troubleshooting. Call a professional HVAC technician.

How to Reset Lennox Code 4

  1. Turn off the furnace power switch, usually located on or near the unit.
  2. Turn off the circuit breaker for the furnace. Wait 30 seconds.
  3. Restore power at the breaker and flip the furnace switch back on.
  4. Set the thermostat to call for heat. If the error code returns after 2-3 ignition attempts, the fault requires repair.

Resetting clears the code from the display but does not fix the underlying fault. If the code returns after reset, proceed to the diagnostic steps above.

What Does Lennox Error Code 4 Mean?

The Lennox 4 error, or High Limit Switch Open, indicates that your HVAC system has detected an abnormally high temperature and has shut down to prevent potential damage to the unit. This is a safety feature designed to protect your system and your home. The high limit switch is a safety device that monitors the temperature of the air leaving your furnace or air handler. If the temperature exceeds the set limit, the switch opens and shuts down the system.

Common Causes

  • A faulty high limit switch
  • A problem with the temperature sensor
  • Blocked or restricted airflow over the heat exchanger
  • A malfunctioning inducer motor or draft inducer fan

Diagnostic Steps

If... Check Expected
The system is not running Measure the voltage at the high limit switch (terminal H) 0 volts
The system is running Check the temperature of the air leaving the furnace or air handler Below 160°F (71°C)

Applicable Lennox Models

Replacement Parts

Part OEM Number Est. Cost Where to Buy
High Limit Switch 34A2011-000
Temperature Sensor

Related Codes on Same Models

Other codes that affect the same Lennox model families as 4.

Code Description Severity
1 Ignition Failure Warning
2 Pressure Switch Stuck Closed Warning
3 Pressure Switch Stuck Open Warning
5 Flame Rollout Switch Open Warning
6 Pressure Switch System Lockout Warning
7 Ignition Lockout Warning
8 Control Board Error Warning
9 Line Voltage Polarity Incorrect Warning
E250 Lennox Code E250 - Indoor Blower Communication Error Warning