Goodman Error Code 4: Open High Limit Switch
LED Blink Pattern
LED blinks 4 times.
How to Fix Goodman Code 4
- Step 1: Turn off your HVAC system at the thermostat and the circuit breaker to prevent further operation.
- Step 2: Do not attempt to open or disassemble your HVAC unit. This error requires professional diagnosis and repair.
- Step 3: Contact a licensed HVAC technician to inspect and repair your system.
How to Reset Goodman Code 4
- Turn off the furnace power switch, usually located on or near the unit.
- Turn off the circuit breaker for the furnace. Wait 30 seconds.
- Restore power at the breaker and flip the furnace switch back on.
- Set the thermostat to call for heat. If the error code returns after 2-3 ignition attempts, the fault requires repair.
Resetting clears the code from the display but does not fix the underlying fault. If the code returns after reset, proceed to the diagnostic steps above.
What Does Goodman Error Code 4 Mean?
The Goodman 4 error, also known as an open high limit switch, indicates that your HVAC system has detected an issue with its high limit switch. This switch is designed to monitor the temperature of your system's heat exchanger and prevent it from overheating. When the switch is open, it can't perform its function, leading to potential system damage. This error is typically caused by a faulty switch, but it could also be due to a wiring issue or a problem with the system's temperature sensor.
Common Causes
- Faulty high limit switch
- Wiring issue related to the high limit switch
- Problem with the system's temperature sensor
Diagnostic Steps
| If... | Check | Expected |
|---|---|---|
| The system's blower fan is not running | Measure the voltage at the blower motor terminals using a multimeter | No voltage (open circuit) |
| The system's blower fan is running | Inspect the high limit switch for any visible damage or disconnection | No visible damage or disconnection |
Applicable Goodman Models
Recall Notices
Issued: November 1, 2021
Affected models: Molded plastic evaporator coil drain pans in up-flow condensing gas furnaces
Drain pans can overheat, melt, and deform, posing a fire hazard. Recall expanded January 2024.
Replacement Parts
| Part | OEM Number | Est. Cost | Where to Buy |
|---|---|---|---|
| High Limit Switch | 4BH13-100 | — | Find Part |
Related Codes on Same Models
Other codes that affect the same Goodman model families as 4.
| Code | Description | Severity |
|---|---|---|
| 1 | System Lockout | Warning |
| 2 | Pressure Switch Stuck Closed | Warning |
| 3 | Pressure Switch Stuck Open | Warning |
| 5 | Flame Sensed With Gas Valve Off | Warning |
| 6 | Open Rollout Switch | Warning |
| 7 | Low Flame Signal | Warning |
| 8 | Ignitor Error | Warning |
| CONTINUOUS | Reversed Polarity | Warning |
| F01 | Goodman Code F01 - Ignition Lockout | Critical |
| STEADY-ON | Normal Operation | Info |